aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/power/power_supply_class.txt
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/power/power_supply_class.txt')
-rw-r--r--Documentation/power/power_supply_class.txt20
1 files changed, 20 insertions, 0 deletions
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt
index 211831d..3f10b39 100644
--- a/Documentation/power/power_supply_class.txt
+++ b/Documentation/power/power_supply_class.txt
@@ -81,6 +81,9 @@ This defines trickle and fast charges. For batteries that
are already charged or discharging, 'n/a' can be displayed (or
'unknown', if the status is not known).
+AUTHENTIC - indicates the power supply (battery or charger) connected
+to the platform is authentic(1) or non authentic(0).
+
HEALTH - represents health of the battery, values corresponds to
POWER_SUPPLY_HEALTH_*, defined in battery.h.
@@ -112,14 +115,31 @@ CHARGE_COUNTER - the current charge counter (in µAh). This could easily
be negative; there is no empty or full value. It is only useful for
relative, time-based measurements.
+CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger.
+CONSTANT_CHARGE_CURRENT_MAX - maximum charge current supported by the
+power supply object.
+
+CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger.
+CONSTANT_CHARGE_VOLTAGE_MAX - maximum charge voltage supported by the
+power supply object.
+
+CHARGE_CONTROL_LIMIT - current charge control limit setting
+CHARGE_CONTROL_LIMIT_MAX - maximum charge control limit setting
+
ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
CAPACITY - capacity in percents.
+CAPACITY_ALERT_MIN - minimum capacity alert value in percents.
+CAPACITY_ALERT_MAX - maximum capacity alert value in percents.
CAPACITY_LEVEL - capacity level. This corresponds to
POWER_SUPPLY_CAPACITY_LEVEL_*.
TEMP - temperature of the power supply.
+TEMP_ALERT_MIN - minimum battery temperature alert value in milli centigrade.
+TEMP_ALERT_MAX - maximum battery temperature alert value in milli centigrade.
TEMP_AMBIENT - ambient temperature.
+TEMP_AMBIENT_ALERT_MIN - minimum ambient temperature alert value in milli centigrade.
+TEMP_AMBIENT_ALERT_MAX - maximum ambient temperature alert value in milli centigrade.
TIME_TO_EMPTY - seconds left for battery to be considered empty (i.e.
while battery powers a load)